FEM5KMS1FA1-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA1:

    • One contact moved by actuator (1NC)
    • Three contacts moved by solenoid (1NO + 2NC)

    FEM5KMS1FA2-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA2:

    • One contact moved by actuator (1NO)
    • Three contacts moved by solenoid (1NO + 2NC)

    FEM5KMS1FA3-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V DC

    Microswitch FA3:

    • Two contacts moved by actuator (1NO + 1NC)
    • Two contacts moved by solenoid (2NC)

    FEM5KMS1FA4-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA4:

    • Two contacts moved by actuator (1NO + 1NC)
    • Two contacts moved by solenoid (1NO+1NC)

    FEM5KMS1FA5-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA5:

    • One contact moved by actuator (1NC)
    • Three contacts moved by solenoid (3NC)

    FEM5KMS1FA6-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA6:

    • One contact moved by actuator (1NO)
    • Three contacts moved by solenoid (3NC)

    FEM5KMS1FA7-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA7:

    • Two contacts moved by actuator (2NC)
    • Two contacts moved by solenoid (1NO+1NC)

    FEM5KMS1FA8-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA8:

    • Two contacts moved by actuator (2NC)
    • Two contacts moved by solenoid (2NC)

    FEM5KMS1FA9-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FA9:

    • Two contacts moved by actuator (2NO)
    • Two contacts moved by solenoid (2NC)

    FEM5KMS1FB1-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FB1:

    • Four contacts moved by solenoid (4NC)

    FEM5KMS1FB2-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FB2:

    • Four contacts moved by actuator (4NC)

    FEM5KMS1FB3-230E

    Electromagnetic safety switch with separated actuator – Metal casing and metal head – Standard frontal head orientation 0° – 90°/180°/270° rotatable

    Electrical interlock: actuator blocked when the solenoid is excited.

    Manual release: It is possible to unlock the device by using the key on the cover

    Solenoid supply voltage: 230V AC/DC

    Microswitch FB3:

    • Three contacts moved by actuator (3NC)
    • One contact moved by solenoid (1NC)