- Display 15 Products per page
FEP5KP1FA1-120E-A30
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA1:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (2NC + 1NO)
A30 – Rear escape release (L=30mm)
FEP5KP1FA1-120E-A45
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA1:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (2NC + 1NO)
A45 – Rear escape release (L=45mm)
FEP5KP1FA1-120E-A60
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA1:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (2NC + 1NO)
A60 – Rear escape release (L=60mm)
FEP5KP1FA2-120E-A30
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA2:
One contact moved by actuator (1NO)
Three contacts moved by solenoid (1NO + 2NC)
A30 – Rear escape release (L=30mm)
FEP5KP1FA2-120E-A45
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA2:
One contact moved by actuator (1NO)
Three contacts moved by solenoid (1NO + 2NC)
A45 – Rear escape release (L=45mm)
FEP5KP1FA2-120E-A60
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA2:
One contact moved by actuator (1NO)
Three contacts moved by solenoid (1NO + 2NC)
A60 – Rear escape release (L=60mm)
FEP5KP1FA3-120E-A30
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA3:
Two contacts moved by actuator (1NO + 1NC)
Two contacts moved by solenoid (2NC)
A30– Rear escape release (L30mm)
FEP5KP1FA3-120E-A45
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA3:
Two contacts moved by actuator (1NO + 1NC)
Two contacts moved by solenoid (2NC)
A45– Rear escape release (L45mm)
FEP5KP1FA3-120E-A60
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA3:
Two contacts moved by actuator (1NO + 1NC)
Two contacts moved by solenoid (2NC)
A60– Rear escape release (L60mm)
FEP5KP1FA4-120E-A30
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA4:
Two contacts moved by actuator (1NC + 1NO)
Two contacts moved by solenoid (1NC + 1NO)
A30 – Rear escape release (L=30mm)
FEP5KP1FA4-120E-A45
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V DC
Microswitch FA4:
Two contacts moved by actuator (1NC + 1NO)
Two contacts moved by solenoid (1NC + 1NO)
A45 – Rear escape release (L=45mm)
FEP5KP1FA4-120E-A60
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA4:
Two contacts moved by actuator (1NC + 1NO)
Two contacts moved by solenoid (1NC + 1NO)
A60 – Rear escape release (L=60mm)
FEP5KP1FA5-120E-A30
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA5:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (3NC)
A30 – Rear escape release (L=30mm)
FEP5KP1FA5-120E-A45
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA5:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (3NC)
A45 – Rear escape release (L=45mm)
FEP5KP1FA5-120E-A60
Electromagnetic safety switch with separated actuator – Termoplastic casing and termoplastic head – Standard head orientation 0°
Electrical interlock: actuator blocked when the solenoid is excited.
Solenoid supply voltage: 120V AC/DC
Microswitch FA5:
One contact moved by actuator (1NC)
Three contacts moved by solenoid (3NC)
A60 – Rear escape release (L=60mm)