<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Safety Modules &#8211; Comepi Srl</title>
	<atom:link href="https://www.comepi.it/en/categoria-prodotto/dispositivi-di-sicurezza-eng/safety-modules-2/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.comepi.it/en/</link>
	<description></description>
	<lastBuildDate>Wed, 02 Apr 2025 15:03:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://www.comepi.it/wp-content/uploads/2024/06/cropped-comepi-favicon-32x32.jpg</url>
	<title>Safety Modules &#8211; Comepi Srl</title>
	<link>https://www.comepi.it/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MT1A22-024</title>
		<link>https://www.comepi.it/en/prodotto/mt1a22-024/</link>
		
		<dc:creator><![CDATA[Comepi_edit]]></dc:creator>
		<pubDate>Thu, 13 Feb 2025 15:33:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/?post_type=product&#038;p=64311</guid>

					<description><![CDATA[Safety module with delayable outputs on de-energization Electromechanical outputs: 2NO delayable+ 2NO instantaneous Safety level up to PLe (CAT3 for delayed contacts, CAT4 for instantaneous contacts) Delay selectable from 0 to 30s Dual channel or single channel operation Configurable for MANUAL START and AUTOMATIC START Possibility of receiving OSSD signals and electromechanical contacts as input]]></description>
										<content:encoded><![CDATA[<p>Safety module with delayable outputs on de-energization</p>
<p>Electromechanical outputs: 2NO delayable+ 2NO instantaneous</p>
<p>Safety level up to PLe (CAT3 for delayed contacts, CAT4 for instantaneous contacts)</p>
<p>Delay selectable from 0 to 30s</p>
<p>Dual channel or single channel operation</p>
<p>Configurable for MANUAL START and AUTOMATIC START</p>
<p>Possibility of receiving OSSD signals and electromechanical contacts as input</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS1E41-024</title>
		<link>https://www.comepi.it/en/prodotto/ms1e41-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:41:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms1e41-024/</guid>

					<description><![CDATA[Safety unit for expansion of the safety outputs of safety modules 4 NO safety contacts + 1 cNC signalling contacts Two channel configuration useful for safety systems up to PL e* (according to EN ISO 13849-1) Safety category CAT 4* (according to EN ISO 13849-1) – MTTFd 363,4 years – PFHd 1,59 E-10 – DCavg [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety unit for expansion of the safety outputs of safety modules</p>
<p>4 NO safety contacts + 1 cNC signalling contacts</p>
<p>Two channel configuration useful for safety systems up to PL e* (according to EN ISO 13849-1)</p>
<p>Safety category CAT 4* (according to EN ISO 13849-1) – MTTFd 363,4 years – PFHd 1,59 E-10 – DCavg 99%*</p>
<p>*Safety performances reachable using with a COMEPI MS1, MT2, MS2 safety module with proper connection.</p>
<p>Configurable for MANUAL START, AUTOMATIC START e MONITORED START</p>
<p>Plastic casing – IP20 – Supply voltage 24V AC/DC</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS1H21-024</title>
		<link>https://www.comepi.it/en/prodotto/ms1h21-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:41:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms1h21-024/</guid>

					<description><![CDATA[Safety Module –Suitable for control of two hands command stations IIIC category device with Synchronism control according to the requirements of standard EN ISo 13851 2NO safety outputs + 1NC signalling coutput + 1 PNP auxiliary output (24Vdc/50mA) Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1) (secondo [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety Module –Suitable for control of two hands command stations</p>
<p>IIIC category device with Synchronism control according to the requirements of standard EN ISo 13851</p>
<p>2NO safety outputs + 1NC signalling coutput + 1 PNP auxiliary output (24Vdc/50mA)</p>
<p>Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1) (secondo EN ISO 13849-1)</p>
<p>Safety category CAT 4 (According to EN ISO 13849-1) – MTTFd 422,1 anni – PFHd 1,35 E-10 – DCavg 99%</p>
<p>&lt;Plastic casing – IP20 – Supply voltage 24V AC/DC</p>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS1B31-024</title>
		<link>https://www.comepi.it/en/prodotto/ms1b31-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:41:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms1b31-024/</guid>

					<description><![CDATA[Safety Module with antivalent inputs – Suitable for control of safety limit switches and safety magnetic sensors mounted with antivalent contacts (1NO+1NC) mounted on Safety Guards. 3 NO Safety Outputs + 1 NC Signalling output Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1) Safety cathegory CAT 4 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety Module with antivalent inputs – Suitable for control of safety limit switches and safety magnetic sensors mounted with antivalent contacts (1NO+1NC) mounted on Safety Guards.</p>
<p>3 NO Safety Outputs + 1 NC Signalling output</p>
<p>Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1)</p>
<p>Safety cathegory CAT 4 (according to EN ISO 13849-1) – MTTFd 420,8 anni – PFHd 1,85 E-10 – DCavg 99%</p>
<p>Configurable for MANUAL START, AUTOMATIC START e MONITORED START</p>
<p>Plastic casing – IP20 – Supply voltage 24V AC/DC</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS1A20-024</title>
		<link>https://www.comepi.it/en/prodotto/ms1a20-024-2/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:41:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms1a20-024-2/</guid>

					<description><![CDATA[Safety Module – Useful to control inputs as safety limit switches, solenoid commanded interlocks, safety magnetic sensors, emergency stop devices, safety gates Conform to LIFT Directive according to reference standards EN 81-20 and EN 81-50 2 NO Safety Outputs Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1) [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety Module – Useful to control inputs as safety limit switches, solenoid commanded interlocks, safety magnetic sensors, emergency stop devices, safety gates</p>
<p>Conform to LIFT Directive according to reference standards EN 81-20 and EN 81-50</p>
<p>2 NO Safety Outputs</p>
<p>Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1)</p>
<p>Safety category CAT 4 (according to EN ISO 13849-1) – MTTFd 420,8 anni – PFHd 1,85 E-10 – DCavg 99%</p>
<p>Configurable for MANUAL START, AUTOMATIC START e MONITORED START</p>
<p>Plastic casing – IP20 – Supply voltage 24V AC/DC</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS2A31-024</title>
		<link>https://www.comepi.it/en/prodotto/ms2a31-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:38:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms2a31-024/</guid>

					<description><![CDATA[Safety module – Suitable for control of limit switches for safety gates, safety magnetic sensors, emergency stops and electro-sensitive protection devices ESPE 3 safety NO OSSD outputs + 1 signalling NC OSSD output 2 channel configuration for safety systems up to SIL 3 (according to EN62061) and PL e (according to EN ISO 13849-1) MANUAL [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety module – Suitable for control of limit switches for safety gates, safety magnetic sensors, emergency stops and electro-sensitive protection devices ESPE</p>
<p>3 safety NO OSSD outputs + 1 signalling NC OSSD output</p>
<p>2 channel configuration for safety systems up to SIL 3 (according to EN62061) and PL e (according to EN ISO 13849-1)</p>
<p>MANUAL START or AUTOMATIC START configuration</p>
<p>Plastic casing – IP20 – Supply voltage 24V DC</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MS2A40-024</title>
		<link>https://www.comepi.it/en/prodotto/ms2a40-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:38:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/ms2a40-024/</guid>

					<description><![CDATA[Safety module – Suitable for control of limit switches for safety gates, safety magnetic sensors, emergency stops and electro-sensitive protection devices ESPE 4 safety NO OSSD outputs 2 channel configuration for safety systems up to SIL 3 (according to EN62061) and PL e (according to EN ISO 13849-1) MANUAL START or AUTOMATIC START configuration Plastic [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Safety module – Suitable for control of limit switches for safety gates, safety magnetic sensors, emergency stops and electro-sensitive protection devices ESPE</p>
<p>4 safety NO OSSD outputs</p>
<p>2 channel configuration for safety systems up to SIL 3 (according to EN62061) and PL e (according to EN ISO 13849-1)</p>
<p>MANUAL START or AUTOMATIC START configuration</p>
<p>Plastic casing – IP20 – Supply voltage 24V DC</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MT2A22-024</title>
		<link>https://www.comepi.it/en/prodotto/mt2a22-024/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:38:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/mt2a22-024/</guid>

					<description><![CDATA[Multifuncton safety module with delayed outputs – Suitable for commanding interlocking devices with guards, associated with machinery with inertia, where the dangerous situation can last for a defined time after stop signal generation 2 safety NO OSSD delayed outputs + 2 safety NO OSSD instantaneous outputs 2 channel configuration for safety systems up to SIL [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Multifuncton safety module with delayed outputs – Suitable for commanding interlocking devices with guards, associated with machinery with inertia, where the dangerous situation can last for a defined time after stop signal generation</p>
<p>2 safety NO OSSD delayed outputs + 2 safety NO OSSD instantaneous outputs</p>
<p>2 channel configuration for safety systems up to SIL 3 (according to EN62061) and PL e (according to EN ISO 13849-1)</p>
<p>MANUAL START or AUTOMATIC START configuration</p>
<p>Plastic casing – IP20 – Supply voltage 24V DC</p>
]]></content:encoded>
					
		
		