<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FEP-120M &#8211; Comepi Srl</title>
	<atom:link href="https://www.comepi.it/en/categoria-prodotto/dispositivi-di-sicurezza-eng/monitoring-of-safety-guards/guard-locking-interlocking-devices/electromagnetic-safety-device/fep/fep-m/fep120-m/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.comepi.it/en/</link>
	<description></description>
	<lastBuildDate>Fri, 02 Aug 2024 19:43:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://www.comepi.it/wp-content/uploads/2024/06/cropped-comepi-favicon-32x32.jpg</url>
	<title>FEP-120M &#8211; Comepi Srl</title>
	<link>https://www.comepi.it/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FEP5KP4FB3-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp4fb3-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp4fb3-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 270° Electrical interlock: actuator blocked when the solenoid is excited. Solenoid supply voltage: 120V AC Microswitch FB3: Three contacts moved by actuator (3NC) One contact moved by solenoid (1NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 270°</p>
<p>Electrical interlock: actuator blocked when the solenoid is excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB3:</p>
<p>Three contacts moved by actuator (3NC)<br />
One contact moved by solenoid (1NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP3FB3-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp3fb3-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:35 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp3fb3-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB3: Three contacts moved by actuator (3NC) One contact moved by solenoid (1NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB3:</p>
<p>Three contacts moved by actuator (3NC)<br />
One contact moved by solenoid (1NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP2FB3-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp2fb3-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp2fb3-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 90° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 24V AC/DC Microswitch FB3: Three contacts moved by actuator (3NC) One contact moved by solenoid (1NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 90°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 24V AC/DC</p>
<p>Microswitch FB3:</p>
<p>Three contacts moved by actuator (3NC)<br />
One contact moved by solenoid (1NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP1FB3-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp1fb3-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp1fb3-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 0° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB3: Three contacts moved by actuator (3NC) One contact moved by solenoid (1NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 0°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB3:</p>
<p>Three contacts moved by actuator (3NC)<br />
One contact moved by solenoid (1NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP4FB2-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp4fb2-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:30 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp4fb2-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 270° Electrical interlock: actuator blocked when the solenoid is excited. Solenoid supply voltage: 24V AC/DC Microswitch FB2: Four contacts moved by actuator (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 270°</p>
<p>Electrical interlock: actuator blocked when the solenoid is excited.</p>
<p>Solenoid supply voltage: 24V AC/DC</p>
<p>Microswitch FB2:</p>
<p>Four contacts moved by actuator (4NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP3FB2-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp3fb2-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp3fb2-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB2: Four contacts moved by actuator (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB2:</p>
<p>Four contacts moved by actuator (4NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP2FB2-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp2fb2-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp2fb2-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 90° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB2: Four contacts moved by actuator (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 90°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB2:</p>
<p>Four contacts moved by actuator (4NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP1FB2-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp1fb2-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:26 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp1fb2-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 0° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB2: Four contacts moved by actuator (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Standard head orientation 0°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB2:</p>
<p>Four contacts moved by actuator (4NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP4FB1-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp4fb1-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp4fb1-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 270° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 24V AC/DC Microswitch FB1: Four contacts moved by solenoid (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 270°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 24V AC/DC</p>
<p>Microswitch FB1:</p>
<p>Four contacts moved by solenoid (4NC)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FEP5KP3FB1-120M</title>
		<link>https://www.comepi.it/en/prodotto/fep5kp3fb1-120m/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 19:43:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.comepi.it/prodotto/fep5kp3fb1-120m/</guid>

					<description><![CDATA[Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180° Mechanical interlock: actuator blocked when the solenoid is not excited. Solenoid supply voltage: 120V AC Microswitch FB1: Four contacts moved by solenoid (4NC)]]></description>
										<content:encoded><![CDATA[<p>Electromagnetic safety switch with separated actuator &#8211; Termoplastic casing and termoplastic head &#8211; Head orientation 180°</p>
<p>Mechanical interlock: actuator blocked when the solenoid is not excited.</p>
<p>Solenoid supply voltage: 120V AC</p>
<p>Microswitch FB1:</p>
<p>Four contacts moved by solenoid (4NC)</p>
]]></content:encoded>
					
		
		